The ABUS Field Logger is a microprocessor based data acquisition and recorder, which can handle any analogue input and will operate as an RTU linked to a PC for online recording and supervision or as a stand alone data logger with real time clock and graph capabilities. DIN rail compatible, it has 8 universal channels that will accept different input sensors at the same time and can be easily expanded.
Accuracy
:
Thermocouple J,K,T,E & N
:
0.2% of range ±1°C.
Thermocouple R,S & B
:
0.25% of range ±3°C.
Pt100
:
0.2% of range.
Mains
:
85 ~ 250V AC (50/60Hz); 100 ~ 250V DC; 24V AC / 24V DC (Optional).
Power Consumption
:
2 VA.
Pt100 Input
: